Pressure |
717 Series |
Measure Pressure |
(Internal sensor) |
Accuracy |
0.05% full scale |
Functions |
Zero, min, max, hold, damp |
|
Note gasses / liquids (non-corrosive) |
|
Fluke 717 1G |
Range |
-1 to 1 psi, (-68.9 mbar to 68.9 mbar, -83 to 6.89 kPa) |
Resolution |
0.0001 psi, 0.001 mbar, 0.0001 kPa |
Over pressure |
5 x full scale |
|
Fluke 717 30G |
Range |
-12 to 30 psi, (-850 mbar to 2 bar, -83 to 206.84 kPa) |
Resolution |
0.001 psi, 0.1 mbar, 0.01 kPa |
Over Pressure |
2 x full scale |
|
Fluke 717 100G |
Range |
-12 to 100 psi, (-850 mbar to 7 bar, -83 to 689.48 kPa) |
Resolution |
0.01 psi, 0.1 mbar, 0.01 kPa |
Over pressure |
2 x full scale |
|
Fluke 717 300G |
Range |
-12 to 300 psi, (-850 mbar to 20 bar, -83 to 2068.42 kPa) |
Resolution |
0.01 psi, 1 mbar, 0.1 kPa |
Over pressure |
375 psi, 25 bar |
|
Fluke 717 500G |
Range |
0 to 500 psi, (0 mbar to 34,7 bar, 0 to 3447.38 kPa) |
Resolution |
0.01 psi, 1 mbar, 0.1 kPa |
Over pressure |
2 x full scale |
|
Fluke 717 1000G |
Range |
0 to 1000 psi, (0 mbar to 69 bar, 0 to 6894.76 kPa) |
Resolution |
0.1 psi, 1 mbar, 0.1 kPa |
Over pressure |
2 x full scale |
|
Fluke 717 1500G |
Range |
0 to 1500 psi, (0 bar to 103.4 bar, 0 to 10342 kPa) |
Resolution |
0.1 psi, 0.01 mbar, 1 kPa |
Over pressure |
2 x full scale |
|
Fluke 717 3000G |
Range |
0 to 3000 psi, (0 bar to 207 bar, 0 to 20684.27 kPa) |
Resolution |
0.1 psi, 0.01 bar, 1 kPa |
Over pressure |
2 x full scale |
|
Fluke 717 5000G |
Range |
0 to 5000 psi, (0 bar to 345 bar, 0 to 34474 kPa) |
Resolution |
0.1 psi, 0.01 bar, 1 kPa |
Over pressure |
2 x full scale |
|
Fluke 717 Series with Pressure Modules |
Measure pressure |
(Via pressure module connector using optional Pressure Modules) |
Range |
29 pressure modules, 0-1 inH20 to 10,000 psi, 2.5 mbar to 700 bar ranges. Over pressure per pressure module specs |
Resolution |
Per pressure module specs |
Accuracy |
Per pressure module specs |
Functions |
Zero, min, max, hold, damp |
Current |
Range |
0 to 24 mA (-25% to 125%) |
Resolution |
0.001 mA |
Accuracy |
0.015% + 2 counts |
Specifications |
Loop power |
Range |
24 V DC |
Accuracy |
±10% |
|
Drive; 20 mA into 1000 ohms for battery > 6.8 V; 700 W for battery 5.8 to 6.8 V |
Display |
Clear 5 digit LCD |
Environmental Specifications |
Operating temperature |
-10°C to 55°C |
Storage temperature |
-40°C to 60°C |
Humidity (without condensation) |
95% (10°C to 30°C) |
75% (30°C to 40°C) |
45% (40°C to 50°C) |
35% (50°C to 55°C) |
Operating altitude |
3,000 M max |
Safety Specifications |
Safety |
CSA C22.2 No. 1010.11992 |
Mechanical and General Specifications |
Size (L x W x H) |
201 x 98 x 52 mm (7.93 x 3.86 x 2.06 in) |
Weight |
22 oz, approximately 600 G with holster |
Warranty |
3 years |
Shock and vibration |
Random, 2 G, 5-500 Hz |
1 m drop test |
Battery type |
Single 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline |